PHOENIX BURNER, PX-100 Heater Inventory #: HT1821 One Phoenix Thermal oil heater; model PX-100, maximum design temperature of 550F. Double Helical coil design with heatmizer fins for improved heat extraction from air stream. The unit will be complete and ready to fire after connecting to the electric, fuel, and hot oil circulation piping. The coil is designed according to ASME for 550F @ 125 psi MAWP. The coils are Schedule 40 SA-106B pipe. This unit comes with a reconditioned burner with a two year warranty on all burner parts. Includes the following specs: 6" inlet/outlet nozzles - ANSI 300# SA 105 WNRF flanges. ASME designed coils = 125 psi @ 550F. Double 3 helical coils. (Sch. 40 SA-106B Seamless pipe). The heater shall have high temperature refractory install in the turn-around area of the heater. Shell and front/back plates to be 304 SS 5/16" steel wrapped with 2" thick high temperature insulation covered with a galvanized steel skin. The heater shall be equipped with a 2" diameter sight glass (quartz) port equipped with a cooling connection located at the rear of the unit for an unobstructed view of the flame. The heater shall be equipped with a 20" (minimum) manway located at the rear door for internal inspection of the unit. The heater shall be equipped with sampling and instrumentation ports to be located on the stack and at locations before and after the convection section. All electrical conduit material shall be rigid aluminum. Controls Controls and control panels to meet NEMA 4 requirements and includes the following: UL Listed NEMA 4 enclosures. TEFC burner blower motor. Honeywell high oil temperature limit control. Love Controls TCS-4010 high stack temperature control. 1 - Stack dual thermocouple. Square D 500SV1B Step-down control transformer for 120V control power. Numbered terminal blocks and enclosed wire raceways. Alarm horn mounted to the control panel. Integrated shutdown permissive. Control Relays. Full set of dry contacts for alarms and statuses for customer use. Push/Pull emergency stop button located on control panel. Locally mounted instruments: Heater Inlet Piping: 1 pressure switch mounted between the heater inlet and outlet for 500 GPM flowrate. 1 - Inlet pressure gauge with shut off cock. 1 - Inlet thermometer with thermowell. 1 Inlet thermocouple. With thermowell. Heater Outlet Piping: 1 - Outlet pressure gauge with shut off cock. 1 - Outlet thermometer with thermowell. 1 - Outlet dual thermocouple with thermowell. 1 Outlet thermocouple with thermowell for circuit coil #1 1 Outlet thermocouple with thermowell for circuit coil #2 1 Flanged pressure relief valve (located on the heater outlet manifold). Pilot Fuel Train (Natural Gas): Pilot fuel train designed to meet typical NFPA-87 / NEC requirements. Pilot fuel tr